VFD & Soft Starter Services

VFD & Soft Starter
Repairing & Installation

Acharya Electrical provides expert Variable Frequency Drive (VFD) and Soft Starter repair, installation, commissioning, and parameter programming services for industrial pumps, motors, fans, and compressors — restoring performance and reducing energy costs.

VFD Repairing Soft Starter Repair New Installation Parameter Programming All Brands
Service Overview

Expert VFD & Soft Starter Solutions

Variable Frequency Drives (VFDs) and Soft Starters are critical components for energy-efficient motor control in pumping, HVAC, and industrial applications. When these devices fail, production halts and energy savings are lost. Quick, reliable repair is essential.

Acharya Electrical's team of trained drive engineers services all major VFD and Soft Starter brands — diagnosing faults at component level, replacing damaged PCBs, IGBTs, gate drivers, and power modules, and commissioning new drives with optimized parameters for maximum energy savings.

  • Component-level VFD & Soft Starter repair
  • IGBT module, gate driver & PCB replacement
  • New VFD & Soft Starter supply & installation
  • Parameter programming & PID tuning
  • SCADA / PLC interface configuration
  • All major brands serviced
Get Repair Quote
All Brands · Fast Turnaround
Our Services

What We Offer

Complete VFD and Soft Starter services from fault diagnosis and component repair to new installation and commissioning.

VFD Repairing

Component-level repair of all VFD brands — diagnosing faults from display errors and overcurrent trips to blown IGBT modules and failed capacitors.

  • Fault code diagnosis & root cause analysis
  • IGBT / diode module replacement
  • Gate driver & control PCB repair
  • DC bus capacitor replacement

Soft Starter Repairing

Expert repair of electronic soft starters — from SCR / thyristor replacement and bypass contactor issues to control card and firing circuit faults.

  • SCR / thyristor module replacement
  • Firing circuit & control card repair
  • Bypass contactor servicing
  • Parameter reset & testing

New VFD Installation

Supply and installation of new VFDs for pumps, motors, fans, and compressors — with panel integration, cabling, and full commissioning.

  • VFD sizing & brand selection
  • Panel mounting & power wiring
  • Input/output reactor & EMC filter
  • Bypass scheme & interlocks

Parameter Programming

Optimized parameter programming and PID tuning for variable torque and constant torque applications — ensuring energy savings and stable process control.

  • Motor nameplate data entry
  • Ramp up / ramp down setting
  • PID controller tuning for flow/pressure
  • Analog & digital I/O configuration

SCADA & PLC Integration

Configuration of VFD communication ports for SCADA/PLC integration — enabling remote speed control, monitoring, and fault logging.

  • Modbus RTU / TCP configuration
  • PROFIBUS & PROFINET setup
  • Remote start/stop & speed reference
  • Fault logging & alarm integration

Annual Maintenance Contract

Preventive maintenance contracts for VFDs and Soft Starters — including periodic inspection, cooling fan replacement, and firmware updates.

  • Bi-annual preventive servicing
  • Cooling fan & filter replacement
  • Firmware & parameter backup
  • Priority emergency response
Brands We Service

All Major Brands Covered

Our engineers are trained and experienced in servicing VFDs and Soft Starters from all leading global and Indian manufacturers.

ABB VFD & Soft Starters
Siemens SINAMICS / SIRIUS
Danfoss VLT / FC Series
Schneider Electric Altivar
Delta Electronics VFD
Yaskawa A1000 / GA700
L&T Emotron / Altivar
Rockwell / Allen Bradley
How We Work

Our Repair Process

A structured 5-step process ensuring every VFD and Soft Starter repair is thorough, reliable, and tested before return.

01

Fault Diagnosis

Full electrical inspection, fault code reading, and component-level testing.

02

Repair Quotation

Detailed repair report with cost estimate and estimated turnaround time.

03

Component Repair

IGBT, PCB, SCR, capacitor or power module replacement and soldering.

04

Load Testing

Full load test on motor simulator verifying output voltage, current & frequency.

05

Site Commissioning

On-site installation, parameter programming, and performance verification.

Why Choose Us?

Key Benefits

Trusted VFD and Soft Starter repair specialists serving industries across Rajasthan and North India.

Fast Turnaround

Most VFD repairs completed within 3–5 working days — minimizing production downtime.

Cost Savings

Component-level repair costs 60–80% less than buying a new drive — significant savings.

All Brands Expertise

Factory-trained engineers for ABB, Siemens, Danfoss, Schneider, Delta, and more.

Warranty on Repairs

All VFD and Soft Starter repairs carry a 3–6 month workmanship warranty.

VFD or Soft Starter Fault?

Contact Acharya Electrical for a fast diagnosis and repair quotation for your VFD or Soft Starter.

Go Back Top